MY CART

Ballasts>>Lutron Ballasts>>EcoSystem

EcoSystem® | dimming to 10%


 

Lutron EcoSystem Ballast
EcoSystem digitally addressable dimming ballasts employ revolutionary technology allowing each device to listen, think, decide, remember, and react to its environment. EcoSystem fluorescent lighting control solutions are built on a simple building block architecture of fluorescent dimming ballasts, sensors, and controls, free from interfaces and power packs. EcoSystem redefines fluorescent lighting control as easy to design, easy to install, easy to maintain, and cost effective.

Ballast Selection Tool

Compatible Lamp Types:

  • T8 linear
  • T8 U-bent
  • T8 reduced wattage
  • T5 linear
  • T5 HO linear
  • T5 twin-tube
  • T4 quad-tube CFL
  • T4 triple-tube CFL
  • Call For Pricing and Availability

       

    Performance

    • Continuous, flicker-free dimming from 100% to 10% (T8, T5, T5 HO, T5 twin-tube) or 5% (T4)
    • Models available for T8, T5, T5 HO, T5 twin-tube, T4 quad-tube lamps, and T4 triple-tube lamps
    • EcoSystem digital link control allows for re-zoning without rewiring
    • Lamps turn on at any dimmed level without flashing to full brightness
    • Miswire protection of EcoSystem digital link
    • Meets FCC Part 18 Non-Consumer requirements for EMI/RFI emissions
    • 100% performance tested including burn-in at the manufacturer
    • 5-year limited warranty with field service commissioning (3-year warranty standard)

    Specifications

    • Lighting management dimming from 100% to 10% (5% for T4) relative light output
    • Universal voltage input (120 V, 220/240 V, 277 V at 50/60 Hz)
    • Smooth and continuous dimming with no visible flicker
    • Total Harmonic Distortion (THD) less than 10%
    • Power factor greater than .95
    • Ballast factor equal to .85 or 1.17 for T8 lamps
    • Ballast factor equal to 1.0 for T5 and T5 HO lamps
    • Ballast factor equal to .95 for T4 lamps
    • Frequency of operation greater than 42 kHz
    • Sound rating: Class A
    • Built-in inrush current-limiting circuitry (maximum of 7 amps at 120 V and 3 amps at 277 V)
    • Minimum lamp starting temperature 10° C (50° F)
    • Maximum ballast case temperature 75° C (167° F)
     

     